Files
Shelly-Loqed-Touch/Document0-Initial_Information_Gathering.md
2026-11-02 11:53:47 +01:00

21 KiB
Raw Permalink Blame History

DOCUMENT 0 - INITIAL INFORMATION GATHERING


Installation of Custom Software

TODO:

  • Check if CFW is installable

0.1 Services Running on the Device

The system consists of four parts that expose services: the lock (inner/motor module), the outer touch module, the bridge, and the cloud backends used by the LOQED and Shelly apps.

Lock

Its only wireless interface is BLE.

Property Value
Advertising name Loqed Inside
Address FF:EC:EE:E7:32:E5, type PUBLIC (fixed, does not rotate)
Advertising Undirected, connectable
Manufacturer data Company ID 0xFFFF (reserved/test ID), payload 0000

The GATT table could be enumerated without pairing and contains three services:

Service Characteristic Properties Notes
Generic Access (0x1800) Device Name (0x2A00) READ, WRITE Value Loqed Inside. Declared writable.
Appearance (0x2A01) READ 0x0000 (unknown)
Peripheral Preferred Connection Parameters (0x2A04) READ ffffffff0000ffff (no preference)
Central Address Resolution (0x2AA6) READ 0x01 (privacy supported, although a public address is used)
Generic Attribute (0x1801) Service Changed (0x2A05) INDICATE
Custom (bdce0001-e90d-4685-b89d-5578cd199a9f) bdce0101-… WRITE Accepted unauthenticated writes (ToothFairy WRLS-GATT-004)
bdce0102-… READ, INDICATE 33 bytes: 0x01 + 32 high-entropy bytes
bdce0103-… WRITE Accepted unauthenticated writes (ToothFairy WRLS-GATT-004)
bdce0104-… READ, INDICATE 97 bytes: 0x01 + 96 high-entropy bytes

The custom service appears to consist of two request/response channels. The readable values look random, which suggests they are encrypted or cryptographic material rather than plaintext state.

This is an assumption based on the data, not yet verified.

According to the bridge firmware analysis, the lock receives commands (lock state changes, time sync, firmware updates in parts) from the bridge over this BLE link.

Wired interfaces

  • UART (115200 8N1): internal link to the touch module carrying a framed binary protocol with display text
  • SWD: debug port of the nRF52840; no connection could be established

Outer Module (Touch)

No wireless services.

Connected to the motor module by cable and receives display content over the UART link described above.

Bridge (ESP32)

The bridge connects to WiFi as a client and relays between the cloud and the lock.

Service / Connection Direction Details
BLE central (GATT client) Bridge → Lock Scans for, pairs/bonds with and controls the lock
MQTT over TLS Bridge → Cloud mqtts://mqtt.production.loqed.com:8883 / production.loqed.com:8883, topics locks/<id>/to_lock, locks/<id>/to_backend, …/state, …/status
HTTPS Bridge → Cloud gateway.production.loqed.com:443, production.loqed.com:8080
HTTPS OTA Bridge → Cloud firmware.loqed.com (firmware for bridge and lock)
Core dump upload Bridge → Cloud https://app.loqed.com/Bridge-core-dump/bridge-core-dump2.php
HTTP (port 80, clear text) LAN → Bridge Likely: 10.12.2.17 (MAC 8c:4b:14:6a:1a:cc, Espressif OUI) answered GET /shelly from the app in the init capture, matches the Shelly local device API and the app's mDNS queries for _shelly._tcp.local
UART console (115200) Physical Boot log, firmware contains format strings that print tokens and WiFi credentials in clear text

Endpoints are taken from the firmware analysis unless stated otherwise.

Cloud Backends

Observed during initial setup.

From the PreTester report of the init capture and the nmap scans:

Host IP Ports observed in capture Notes
control.shelly.cloud 34.95.90.149 443 (TLS 1.3)
shelly-101-eu.shelly.cloud 34.79.5.199 31234 (TLS 1.3) nmap: 22 (OpenSSH 9.6p1 Ubuntu), 80 + 443 (nginx 1.24.0, Ubuntu); 443 returns 401 without WWW-Authenticate header; 31234 filtered
shelly-120-eu.shelly.cloud 104.155.32.247 443, 6113 (TLS 1.3) Rescan pending (see 2.6)
shelly-infra1-eu.shelly.cloud, app-ratings.shelly.cloud, paypal.shelly.cloud 35.205.173.252 443, 9443 (TLS 1.2)
changelog-backend.shelly.cloud 34.62.47.252 443 (TLS 1.2)
repo.shelly.cloud 35.241.201.25 443
integrations.loqed.com 34.155.200.196 443, 8883 (MQTTS)

All cloud connections in the capture were encrypted (TLS 1.2/1.3 with AEAD cipher suites)

The only clear-text HTTP flows were captive-portal checks and the local request to 10.12.2.17:80.

Apps

App Package
LOQED com.loqed.keychain
Shelly cloud.shelly.smartcontrol

0.2 Hardware and Software Specifications

Component Main chip Firmware Interfaces
Lock (inner/motor module) Nordic nRF52840 Unknown (not extracted) BLE, UART, SWD, I²C
Outer module (touch) Unknown (not opened, glued) Unknown Cable to motor module (UART)
Bridge ESP32-WROVER-B LoqedBridge, ESP-IDF v4.4.1 WiFi, BLE, UART

Power supply: 8× AA batteries (lock).

The bridge has its own mains power supply beneath the PCB.

Lock (Inner/Motor Module)

Item Details
SoC Nordic nRF52840
CPU / memory Arm Cortex-M4F @ 64 MHz, 1 MB internal flash, 256 KB RAM, BLE 5 radio (datasheet values)
External flash Macronix MX25R3235F, 4 MB SPI NOR, ultra-low-power, WSON-8 package (U6)
PCB markings LOQED IM31201218 PT2256A4 13Jul2022, manufacturer marking HT-M E327182, 94V0 (flammability rating)
U7 (H451) SOP-8 next to a 0.22 Ω shunt resistor (R220) and the motor/power connectors, likely part of the motor driver or power stage (unverified)
U4 Sensor on I²C (SDA/SCL pads), function unverified
Other components Buzzer, push button (S1), LED, motor terminals (M1/M2), battery terminals (+/−), connectors for touch module, power supply and motor
Debug / test points SWD (CLK, DIO, 3V3), 2×5 pad header (likely factory programming), UART (Rx, Tx, VCC, J2: GND, 3V3, RX, TX, VEXT)
Mechanics DC gear motor driving a brass worm wheel with a hexagonal shaft for the cylinder
Firmware Not extracted, per the bridge firmware, lock updates are downloaded by the bridge from firmware.loqed.com and streamed to the lock over BLE in parts
Lock states (from bridge firmware) Positions: open / latch / night lock, Triggers: twist assist, touch-to-lock, outside module button/PIN, BLE, remote

Outer Module (Touch)

Item Details
Construction Plastic shell, three screws, additionally glued, not opened to avoid damage
Function Touch sensor and display (shows e.g.: "Touch to Lock", "Locking")
Connection Cable to the motor module, display content is sent over UART

Bridge

Item Details
Module Espressif ESP32-WROVER-B (ESP32-D0WD, 64 Mbit PSRAM), WiFi 2.4 GHz + Bluetooth/BLE
Flash 4 MB, MD5 847d4795ee64714d3b02e2bdb3d20266
Framework ESP-IDF v4.4.1, project LoqedBridge
Build Git commit 33beadfc1ba5d4d3b0cb6a6ee673535a1d12972c, version string 33beadf-dirty (built from an uncommitted working tree)
Security features secure_boot_v1 (per boot log), NVS encryption (nvs_key partition)
Partitions nvs (16K), nvs_key (4K), otadata (8K), phy_init (4K), factory / ota_0 / ota_1 (1280K each), coredump (64K)
Update mechanism HTTPS OTA with A/B partitions and rollback, for both bridge and lock
Crypto library mbedTLS (AES, RSA, EC, SHA-1/SHA-256), standard CA trust store bundled, no embedded private keys
Debug interface UART (115200), used for boot log and firmware read-out via esptool
Other Reset button, developer paths leaked in strings (/home/pierre/bridge/…, /root/bridge/…)

0.3 Known Vulnerabilities / Problems / Hacks

No known vulnerabilities or hacks were found during research or on CVE.

Common issues for consumers include:

  • Touch display glitches/freezing
  • Fast battery depletion
  • Insufficient motor power/jams
  • No response from lock/bridge disconnections

0.4 Collecting APKs

Using the rooted Google Pixel and adb, I was able to obtain the Shelly app.:

adb pull $(adb shell pm path cloud.shelly.smartcontrol | tr -d '\r') ./shelly.apk

Additionally, I found out that there is a specific LOQED app as well, which I also obtained:

adb pull $(adb shell pm path com.loqed.keychain | grep base.apk | tr -d '\r') ./loqed.apk

1.1 && 2.1 Unpacking

The packaging contains:

  • A user and safety guide
    • The guide explains installation without any pictures but uses pictures to explain the app setup - why?
    • Video installation guide
  • 8 AA batteries for power supply
  • An outdoor module (touch)
  • Mounting HW (screws, rings, screwdrivers, ...)
  • A lock cylinder
  • A bridge
  • A motor module
  • An indoor module (the lock)
  • The shell

The lock is surrounded by a plastic packaging with molds for eah component. Within the box it is kept in place with some cardboard. The box itself is held shut by a small magnet.

Contents of the box

1.2 || 2.2 Outer Inspection

Outer Module

The outer module is a touch sensor surrounded by a plastic shell with two screws and one cable inside.

Back of the touch module

During installation, the cable is supposed to connect to the motor module.

Cable position of the touch module

Inner Module

The inner module includes the motor module, which is connected using cables to:

  • the power supply
  • the touch module
The inner module including the motor module

Unopened, it is surrounded by a metal shell which can easily be removed by pulling a plastic strap, as this is necessary during installation.

Bridge

The bridge is to be placed within 3 meters of the lock. It is used to connect the lock to the app. It features a reset button.

The bridge

1.3 && 1.4 Open Casing / HW Inspection

Bridge

The plastic enclosure of the bridge can be opened by unscrewing two screws, revealingthe PCB.

What you can spot immediately is:

  • UART
  • ESP32 WROVER B
PCB inside the bridge

Under the PCB is HW for the power supply.

Power supply beneath PCB

Outer Module

There are three screws on the back of the touch module, however, it's additonally glued together. It can't be opened without being (probably) permanently damaged.

Back of the touch module with screws removed

Inner Module

As I'm working with an already opened device, I'm not interiley sure hw many screws were intially needed to open the motor module, but I'm assuming it were four. After unscrewing these the plastic shell can be removed by gently wiggling it until it comes loose.

Inside of the motor module

Once again you can immedatiely spot UART.

After unplugging all cables, the PCB can be leveraged out of the shell with a flat screwdriver, without causing any damage.

Other side of the motor module PCB

Here you can see:

  • UART
  • I^2C
  • Most likely an nRF52840
  • A buzzer and a button

1.5 Software Components from Firmware Analysis

Only the bridge firmware could be extracted, so this section covers the bridge The components below were identified through static analysis.

Apart from ESP-IDF, no component versions are embedded as strings, the versions of the bundled libraries follow from the ESP-IDF release.

Bridge

Component Version / Source Evidence Purpose
ESP-IDF v4.4.1 Version string in image Espressif's SDK and build framework
FreeRTOS Bundled with ESP-IDF v4.4.1 Part of every ESP-IDF application Real-time operating system
Bluedroid BLE stack Bundled with ESP-IDF esp_ble_gattc_*, ESP_GAP_BLE_AUTH_CMPL_EVT BLE central: scanning, pairing/bonding, GATT client to the lock
WiFi driver Bundled with ESP-IDF ap.authmode, ap.passwd, "Set WiFi credentials" WiFi station; credentials provisioned and stored in NVS
mbedTLS Bundled with ESP-IDF mbedTLS label tables, SHA-256 constants, AES/RSA/EC code, TLS-PSK paths TLS and cryptography
CA certificate store Standard ESP/mbedTLS bundle Public CA certificates (Entrust, COMODO, Starfield, …) TLS server certificate validation
MQTT client ESP-IDF MQTT component (likely esp-mqtt) mqtts:// URLs, MQTT auth error strings Cloud connection to mqtt.production.loqed.com:8883
HTTP client / HTTPS OTA ESP-IDF esp_http_client, esp_https_ota esp_https_ota_* Firmware downloads for bridge and lock
OTA / app update ESP-IDF app_update otadata, ota_0 / ota_1 partitions, rollback, image magic 0xE9 A/B updates with rollback
NVS with encryption ESP-IDF nvs_flash nvs and nvs_key (subtype 0x04) partitions Encrypted storage of device identity, tokens and WiFi credentials
Secure boot ESP-IDF secure boot v1 secure_boot_v1 in boot log Bootloader/app signature verification
Core dump ESP-IDF espcoredump coredump partition, upload URL Crash dumps, uploaded to app.loqed.com
Button driver iot_button from Espressif's esp-iot-solution Path components/button_driver/iot_button.c Reset button handling
LoqedBridge application Custom, commit 33beadf (-dirty) Project name, git hash BLE ↔ MQTT relay, command protocol, lock/bridge OTA logic

The custom application implements:

  • a binary command protocol between backend, bridge and lock (REQUEST_STATUS_INFO_BRIDGE, COMMAND_ELECTRONIC_DOOR, COMMAND_LOCK_FIRMWARE_UPGRADE, REQUEST_TIME_FROM_BRIDGE, …)
  • the lock state machine (GO_TO_STATE_*: open / latch / night lock via twist assist, touch-to-lock, outside module, BLE or remote)
  • lock firmware delivery: the bridge downloads lock firmware from firmware.loqed.com and sends it to the lock over BLE in parts

Security-Relevant Observations

  • The firmware prints tokens and WiFi credentials to the UART console (token: %s, auth_token: %s, Setting wifi credentials to:)
  • It was built from an uncommitted working tree (-dirty), and developer paths are left in the binary (/home/pierre/bridge/…, /root/bridge/…)
  • ESP-IDF v4.4.1 is from 2022, the bundled components (Bluedroid, mbedTLS, WiFi driver) should be checked against known CVEs for that release

Lock (Inner Module)

The lock firmware could not be extracted, so its components are unknown.

What can be said from the outside:

  • It runs on the nRF52840, so it is most likely built on Nordic's nRF5 SDK with a SoftDevice or on the nRF Connect SDK (Zephyr)
  • No standard Nordic DFU service is exposed over BLE (ToothFairy WRLS-GATT-002), updates use the bridge's custom transfer mechanism instead
  • It implements a custom GATT service (bdce0001-…) and the UART display protocol to the touch module

1.6 Collect "Fresh" Firmware Dump

The device has been tampered with before, therefore there is no "fresh" dump available.

1.7 && 2.3 Initial setup

The initial setup is done using the LOQED app, the lock can then be integrateed into the Shelly app. The capture can be found here.

Additionally, the Shelly app offers to download the data stored on the device, which you can find here.

Unsure which IP address is most relevant, here are all Shelly-like or LOQED-like addresses:

  • 34.62.47.252: changelog-backend.shelly.cloud0
  • 34.95.90.149: control.shelly.cloud
  • 104.155.32.247: shelly-120-eu.shelly.cloud
  • 34.155.200.196: integrations.loqed.com
  • 35.205.173.252: app-ratings.shelly.cloud, paypal.shelly.cloud, shelly-infra1-eu.shelly.cloud
  • 34.79.5.199: shelly-101-eu.shelly.cloud
  • 35.241.201.25: repo.shelly.cloud

For the PreTester analysis, I chose control.shelly.cloud, as I suspect the lock to communicate to a cloud via the bridge. As the bridge has a built in ESP32 supporting WiFi, I suspect the communication looks as follows:

PlantUML sequence diagram of suspected communication flow

The PreTester report didn't find anything unusual. It reported no critical or high findings.

Old Initial Setup Capture

You can also find an older initial setup capture made by Manu here. I tested this in the PreTester as well using integrations.loqed.com, as this seemed to be the most present IP in the capture.

The report can be found here. Once again, it reported no critical or high findings.

The old init capture supposedly was the first real fresh setup. As mentioned, the lock has been tempered with before.

2.6 Port Scan

I used the PreTester to probe all URLs and endpoints, here are some (interesting) findings:

While most of ports are common for HTTPS and SSH, there are a few interesting ones:

  • 31234 onshelly-101-eu.shelly.cloud: Nmap scan revealed no more information
  • 6113 on shelly-120-eu.shelly.cloud: Nmap scan found ports 6115, 6022, 8007, 6114
    • It may be important to note that scan took significantly more time (almost 1h) and was eventually aborted
    • #TODO: RESCAN
  • 9443 on shelly-infra1-eu.shelly.cloud: widely recognized as an alternative or administrative HTTPS port
  • 8883 on mqtt.production.loqed.com: official standard port designated for MQTT over TLS (MQTTS)

Some playing around with Metasploit's check on these 2 cloud endpoints couldn't find anything either.

2.7 BLE

I ran ToothFairy on the lock. It's advertising name is "Loqed Inside" and it uses a fixed MAC address FF:EC:EE:E7:32:E5. I obtained the GATT table and a very incomplete test report, due to a lack of HW.

However, ToothFairy labelled WRLS-FUZZ-002 as FAIL, due to the target not recovering after malformed packets were sent.

Sniffing

After obtaining the needed HW, I tried snifing the app connection process and sent a lock/unlock command, none of which showed ATT protocol packets. This could be due to:

  • Encryption on the link layer
  • The sniffer struggling with frequency hopping (nRF nordic)

1.8 Collect Firmware Dump of Firmware after initial Setup

Bridge

Hooking up the bridge using UART with a baud rate of 15200 revealed its boot process. Using an older version of esptool, I was able to obtain the firmware:

pipx run --spec esptool==3.3.2 esptool.py -p /dev/ttyUSB1 -b 115200 read_flash 0 0x400000 full_firmware.bin

Writing this down in case I need it again.

FW Analysis

I found an IoT FW analysis tool on GitHub, which I used for generating a quick report.

Reverse Engineer Anything

Using REA, we ran the firmware through Claude Code and received a short report.

Inner Module

Using UART with a baud rate of 115200, I was able to log the boot process & runtime traffic. It seems that the UART link is used for displaying text onto the touch module's display, as you can see it writing whatever the touch module is currently showing. E.g.: "Touch To Lock" or "Locking". Inspect the data here.

In picocom, the device didn't react to any text-based commands.

I also wasn't able to obtain the FW using the test clip from the H451 chip (unknown by mini programmer) or the NOR flash (couldn't grab it).

I tried SWD using the j-link mini, but it kept resulting in an error.

It seems the extraction of the motor module FW exceeds this test.

1.9 && 2.4 Firmware Update / 1.10 Collect Updated Firmware Dump

There is no FW update available.

1.11 Collect Firmware Dump after Factory Reset

Bridge

You can find the firmware after a full reset here.

I generated a report using the same IoT FW analysis tool.

These are the differences:

  • After reset: MD5 a3ae4e32c155426e5a163429fd35ce74
    • Before: MD5 847d4795ee64714d3b02e2bdb3d20266
  • Not byte-for-byte identical, firmware itself is unchanged
  • Only differing string is a single value (MMNHB<84 vs LLNHB<84)

Further & deeper analysis of the FW will be done later on as it exceeds a "simple" informartion gathering.

2.5 Inspection of Device During Normal Usage

The lock works as expected, the only issue seems to be the touch module which is often delayed or doesn't properly react to input.

Nothing interesting other than that.