add: swd/uart attempts on inner module
This commit is contained in:
@@ -222,11 +222,15 @@ Interesting findings:
|
||||
|
||||
### Inner Module
|
||||
|
||||
Using UART with a baud rate of 15200, I was able to log the boot process, you can find it [here](firmware/inner_module/boot.txt).
|
||||
Using UART with a baud rate of 115200, I was able to log the boot process & runtime traffic.
|
||||
It seems that the UART link is used for displaying text onto the touch module's display, as you can see it writing whatever the touch module is currently showing. E.g.: "Touch To Lock" or "Locking". Inspect the data [here](firmware/inner_module/inner_module_uart.txt).
|
||||
|
||||
In picocom, the device didn't react to any text-based commands.
|
||||
The boot log contains repeating binary control structures rather than scrolling text, indicating there is no active console listening in that UART interface.
|
||||
|
||||
I also wasn't able to obtain the FW using the test clip from the H451 chip (unknown by mini programmer) or the NOR flash (couldn't grab it).
|
||||
|
||||
I tried SWD using the j-link mini, but it kept resulting in an error.
|
||||
|
||||
I also wasn't able to obtain the FW using the "Kralle" from the H451 chip or the NOR flash.
|
||||
It seems the extraction of the motor module FW exceeds this test.
|
||||
|
||||
## 1.9 && 2.4 Firmware Update / 1.10 Collect Updated Firmware Dump
|
||||
|
||||
Reference in New Issue
Block a user